ASDA-B2
Chapter 7 Servo Parameters
Revision September 2013
7-83
Group 4: P4-xx Diagnosis Parameters
P4-00
★
ASH1 Fault Record (N)
Address: 0400H
0401H
Operation
Interface:
Keypad / Software
Communication
Related Section:
Section 4.4.1
Default:
0
Control
Mode:
ALL
Unit: N/A
Range: N/A
Data Size: 32-bit
Display
Format:
Hexadecimal
Settings:
This parameter is used to set the most recent fault record.
Display of Low Word: LXXXX: It indicates the fault code, i.e. alarm code
Display of High Word: hYYYY: Reserved.
P4-01
★
ASH2 Fault Record (N-1)
Address: 0402H
0403H
Operation
Interface:
Keypad / Software
Communication
Related Section:
Section 4.4.1
Default:
0
Control
Mode:
ALL
Unit: N/A
Range: N/A
Data Size: 32-bit
Display
Format:
Hexadecimal
Settings:
This parameter is used to set the second most recent fault record.
Display of Low Word: LXXXX: It indicates the fault code, i.e. alarm code.
Display of High Word: hYYYY: It indicates the CANopen error code.
P4-02
★
ASH3 Fault Record (N-2)
Address: 0404H
0405H
Operation
Interface:
Keypad / Software
Communication
Related Section:
Section 4.4.1
Default:
0
Control
Mode:
ALL
Unit: N/A
Range: N/A
Data Size: 32-bit
Display
Format:
Hexadecimal
Settings:
This parameter is used to set the third most recent fault record.
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.