Chapter 4 Display and Operation
ASDA-B2
4-6
Revision September 2013
P0-02
Setting
Display Message
Description
Unit
11
Torque input command
[%]
12
Average load
[%]
13
Peak load
[%]
14
Main circuit voltage
[Volt]
15
Ratio of load inertia to Motor inertia
(Please note that if the display is 130,
it indicates that the actual inertia is
13.0)
[0.1times]
16
IGBT temperature
[
o
C]
17
Resonance frequency (The low byte
is the first resonance point and the
high byte is the second resonance
point.)
[Hz]
18
Absolute pulse number relative to
encoder (use Z phase as home). The
value of Z phase home point is 0, and
it can be the value from -5000 to
+5000 pulses.
-
The following table lists the display examples of monitor value:
Display Message
Description
(Dec.)
16-bit
Data
Decimal display. When the actual value is 1234,
the display is 01234.
(Hex.)
Hexadecimal display. When the actual value is
0x1234, the display is 1234.
(Dec. High Byte)
(Dec. Low Byte) 32-bit
Data
Decimal display. When the actual value is
1234567890, the display of high byte is 1234.5
and the display of low byte is 67890.
(Hex. High Byte)
(Hex. Low Byte)
Hexadecimal display. When the actual value is
0x12345678, the display of high byte is h1234
and the display of low byte is L5678.
Negative value display. When the actual value is -12345,
the display is 1.2.345. (The negative value display is
displayed to indicate a decimal negative value. There is
no negative value display for a hexadecimal negative
value.)