ASDA-B2
Chapter 6 Control Modes of Operation
Revision September 2013
6-9
Electronic Gear Ratio
Corresponding travel distance per
pulse
When the electronic
gear ratio is not
used
=
1
1
=
3x 100 0
4x 250 0
=
300 0
100 00
m
When the electronic
gear ratio is used
=
1000 0
300 0
= 1 m
6.2.4 Low-pass Filter
Relevant parameters:
P1-08
PFLT
Smooth Constant of Position Command (Low-
pass Filter)
Address: 0110H
0111H
Operation
Interface:
Keypad/Software
Communication
Related Section:
Section 6.2.4
Default:
0
Control
Mode:
PT
Unit: 10ms
Range: 0 ~ 1000
Data Size: 16-bit
Display
Format:
Decimal
Settings: 0: Disabled
For example: 11=110 msec
PF LT
Tar get pos ition
Position
Time (ms)
VARITEL INGENIERIA ELECTRONICA S.A.
[email protected] - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.