Defaults
none
Command Modes
CONFIGURATION
Command History
Version 8.3.8.10
Introduced on the S4810.
Version 7.5.1.0
Added support for multicast-bandwidth.
Version 7.4.1.0
and 6.5.3.0
Introduced on the E-Series.
Usage
Information
This command does not uniquely identify a queue, but rather identifies only a set of queues.
The WRED curve is applied to all eight egress Multicast queues.
Important Points to Remember — Multicast-Bandwidth Option
•
A unique multicast weighted fair queuing (WFQ) setting can be applied only on a per
port-pipe basis. The minimum percentage of the multicast bandwidth assigned to any
of the ports in the port-pipe takes effect for the entire port-pipe.
•
If the percentage of multicast bandwidth is 0, control traffic going through multicast
queues are dropped.
•
The
no
form of the command without
multicast-bandwidth
and
wred-
profile
, removes both the wred-profile and multicast-bandwidth configuration.
•
On 10 Gigabit ports only, the multicast bandwidth option works only if the total unicast
bandwidth is more than the multicast bandwidth.
•
If strict priority is applied along with multicast-bandwidth, the effect of strict priority is
on all ports where unicast and multicast bandwidth are applied.
•
When multicast bandwidth is assigned along with unicast bandwidth, first multicast
bandwidth is reserved for that port, then the remaining unicast bandwidth configured
is adjusted according to the bandwidth available after reserving for multicast
bandwidth.
Related
Commands
show queue statistics egress
– displays the egress queue statistics.
queue ingress
Assign a WRED Curve to all eight ingress Multicast queues or designate the percentage for the Multicast bandwidth
queue.
E-Series, S4810
Syntax
queue ingress multicast {linecard
slot number
port-set
number
|
all} [wred-profile
name
]
To return to the default, use the
no queue ingress multicast {linecard
slot
number
port-set
number
| all} [wred-profile
name
]
command.
Parameters
linecard
number
Enter the keyword
linecard
followed by the line card slot number.
For the E-Series, the range is 0 to 13 on a E1200, 0 to 6 on a E600/E600i,
and 0 to 5 on a E300.
1207
Summary of Contents for Force10 Z9000
Page 1: ...FTOS Command Line Reference Guide for the Z9000 System FTOS 9 1 0 0 ...
Page 96: ...96 ...
Page 194: ...194 ...
Page 312: ...312 ...
Page 540: ...540 ...
Page 546: ...546 ...
Page 560: ...560 ...
Page 566: ...566 ...
Page 590: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated 590 ...
Page 624: ...624 ...
Page 638: ...638 ...
Page 648: ...648 ...
Page 659: ...Related Commands show gvrp displays the GVRP configuration 659 ...
Page 660: ...660 ...
Page 834: ...834 ...
Page 854: ...854 ...
Page 906: ...906 ...
Page 914: ...914 ...
Page 976: ...976 ...
Page 990: ...990 ...
Page 1006: ...1006 ...
Page 1008: ...1008 ...
Page 1026: ...1026 ...
Page 1145: ...10 211 1 2 Outgoing interface list GigabitEthernet 8 0 1145 ...
Page 1146: ...1146 ...
Page 1156: ...1156 ...
Page 1166: ...1166 ...
Page 1180: ...1180 ...
Page 1258: ...1258 ...
Page 1272: ...1272 ...
Page 1394: ...1394 ...
Page 1400: ...1400 ...
Page 1410: ...1410 ...
Page 1424: ...1424 ...
Page 1444: ...1444 ...
Page 1468: ...Version 8 3 8 0 Introduced on the S4810 1468 ...
Page 1470: ...1470 ...