![DEC DECstation 5000 Model 100 Series Maintenance Manual Download Page 94](http://html1.mh-extra.com/html/dec/decstation-5000-model-100-series/decstation-5000-model-100-series_maintenance-manual_2461332094.webp)
Troubleshooting the Keyboard and Mouse
If the system reports an error message that includes misc/kbd
or misc/mouse, the problem is in the keyboard, mouse,
keyboard-mouse cable, or system module. Troubleshoot these
items as follows:
1.
Make sure that the keyboard and mouse are attached
correctly to the keyboard-mouse cable and that the
keyboard-mouse cable is attached correctly to the system
unit.
2.
Repeat the power-up self-test by turning the system unit
power off and then on again.
3.
If the power-up self-test still returns the error message
misc/kbd or misc/mouse, replace the keyboard or the
mouse.
If the error message is misc/kbd, replace the keyboard.
If the error message is misc/mouse, replace the mouse.
4.
If the power-up self-test still returns the error message
misc/kbd or misc/mouse after you replace the problem
item, replace the keyboard-mouse cable. Then repeat the
power-up self-test.
5.
If the power-up self-test returns message code misc/kbd
or misc/mouse after you replace the keyboard, mouse, and
keyboard-mouse cable, replace the system module and
chassis. Refer to ‘‘Replacing a System Module and Chassis’’
earlier in this chapter for directions.
5–16
Basic Hardware
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...