erl Command
Use the erl command to display or clear the log of the first
several errors that occurred since the most recent power-up or
reset. The erl command format is erl [-c]
To display the current error message log, use the erl
command without the -c option.
To clear the error message log, include the -c option when
you type the erl command.
go Command
Use the go command to transfer system control to a specific
system address.
The go command format is go [adress]
To transfer system control to the address specified in the
last boot -n command, type the go command without the
adress parameter. If you omit the parameter adress, and if
no previous boot -n command has been issued, the system
ignores the go command.
To transfer system control to the contents of a specific
address, include the parameter adress. Replace the
parameter adress with the address to which you want
to transfer control.
Console Commands
C–19