Table F-30 (Cont.).
ECC SBE Fix Test Error Codes
Error Code
Meaning
10
ERRADR VALID bit was not set. Error was possibly not
detected.
11
ERRADR CPU bit was not set.
12
ERRADR WRITE bit was set on what should have been a
read error.
13
ERRADR ECCERR bit was not set.
14
ERRADR address does not match check parameters.
15
Checkbit syndrome (CHKSYN) VALID bit was not set.
16
CHKSYN SNGLO bit was not set.
17
Test failed while checking multiple bit error read.
Test Commands and Messages Produced by Version PDE3 ROM Chips
F–25