Real-Time Clock Register Test
The real-time clock register test checks the real-time clock
(RTC) registers. To run the real-time clock register test, type
t 7/rtc/regs and press Return.
Real-time clock register test error messages
Real-time clock register test error messages have the form
?TFL: 7/rtc/regs (code description)
?TFL 7/rtc/regs indicates that the real-time clock register
test reported an error.
code represents a code that identifies the portion of the test
that failed.
description represents additional information that describes
the failure.
Table D-19 describes the additional error codes and descriptions
found in real-time clock register test error messages.
Table D-19.
Real-Time Clock Register Test Error Codes and Descriptions
Error Code and Description
Meaning
1
UIP bit remained set past allotted time.
(2: register =xx, sb yy)
The test failed to write pattern correctly.
The register value is the actual value in the
named register, followed by what the value
should be.
D–30
Test Commands and Messages
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...