Serial Line Single Silo Test
The serial line single silo test checks the serial line controller’s
ability to fill and empty the silo. To run this test, type t f43 P1
P2 and press Return.
Serial line single silo test error messages
Table F-6 describes the parameters in serial line single silo test
commands and error messages.
Table F-7 describes the error codes found in serial line single
silo error messages.
Table F-6.
Serial Line Silo Alarm Test Parameters
Parameter
Description
P1
Specifies the test’s loopback setting. Specify 0 for internal
loopback; specify 1 for external loopback.
P2
Specifies the serial line to be tested.
Specify 0 to test the keyboard.
Specify 1 to test the mouse.
Specify 2 to test the right communications line.
Specify 3 to test the left communications line.
P3
Actual value in register named in the subtest.
P4
Expected value in register named in the subtest.
P5
Baud rate written to the serial line printer.
Table F-7.
Serial Line Single Silo Test Error Codes
Error Code
Meaning
1
Single silo test failed.
2
Timeout occurred while waiting for transmit ready (trdy).
3
Error occurred while checking for correct line in serial line
current status register (CSR).
4
Timeout occurred while waiting for correct line and trdy in
CSR.
5
RBUF- dval + line + received character.
Test Commands and Messages Produced by Version PDE3 ROM Chips
F–7
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...