Table D-4 describes error descriptions used in cache reload test
error messages.
Table D-4.
Cache Reload Test Error Descriptions
Error Description
Meaning
(PE address= xxxxxxxx, sb
yyyyyyyy)
Unexpected parity error occurred. The
address value is the actual value at a
given address, followed by the correct
value.
(PE @ xxxxxx (C))
Parity error occurred. xxxxxx
represents the address where the
error occurred.
Cache Segment Test
The cache segment test checks individual cache segments.
To run the cache segment test, type t 7/cache/seg [cache]
[address] and press Return.
When you type the cache segment test command,
Replace the optional cache parameter with a value that
specifies the cache you want to test.
Specify D to test the D cache.
Specify I to test the I cache.
Replace address with a specific address you want to test.
Note that using the optional address parameter correctly
requires thorough knowledge of the firmware specifications.
Cache segment test error messages
Cache segment test error messages have the form
?TFL: 7/cache/seg (code : description)
?TFL 7/cache/seg indicates that the cache segment test
reported an error.
code represents some code that identifies which portion of
the test failed.
description represents additional information that describes
the failure.
D–8
Test Commands and Messages
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...