![DEC DECstation 5000 Model 100 Series Maintenance Manual Download Page 245](http://html1.mh-extra.com/html/dec/decstation-5000-model-100-series/decstation-5000-model-100-series_maintenance-manual_2461332245.webp)
Ethernet Station Address ROM Test
The ethernet station address ROM (ESAR) test checks the
ethernet station address ROM on the Ethernet controller. To
run the ESAR test, type t x21 and press Return.
ESAR test error codes
Table F-51 lists error codes used in ESAR test error messages.
Table F-51.
ESAR Test Error Codes
Error Code
Description
1
First read to ESAR failed.
2
ESAR contained all zeros.
3
ESAR contained broadcast address.
4
Error occurred computing checksum.
5
Checksum miscompare occurred in lower byte.
6
Checksum miscompare occurred in lower byte.
7
Reverse copy mismatch occurred.
8
Forward copy mismatch occurred.
9
Test pattern FF mismatch occurred.
10
Test pattern 00 mismatch occurred.
11
Test pattern 55 mismatch occurred.
12
Test pattern AA mismatch occurred.
13
Test pattern FF mismatch occurred.
14
Test pattern 00 mismatch occurred.
15
Test pattern 55 mismatch occurred.
16
Test pattern AA mismatch occurred.
Test Commands and Messages Produced by Version PDE3 ROM Chips
F–39
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...