Distinguishing Event Types
The second line of each error log lists the code number and
name of the error log event type.
The following sections describe memory, error and status, and
system overheat error logs. For a detailed explanation of other
error logs that involve the system unit, refer to the ULTRIX
documentation.
Memory error logs
Memory error logs record errors that occur in the memory
modules. This is a sample of the error log sections that are
unique to memory error logs.
----- UNIT INFORMATION -----
UNIT CLASS
MEMORY
UNIT TYPE
KN02 MEMORY
ERROR SYNDROME
MEMORY CRD ERROR
----- ERROR & STATUS REGS -----
EPC
x8006DF4C
KN02 STAT REG
x07C20001
IO INT 0 PENDING
19,200 BAUD
8 MB MEM MODULE
ECC CMD x0
IO INT 1 ENABLED
IO INT 6 ENABLED
IO INT 7 ENABLED
NORMAL MODE
REFRESH EVEN MEM MODULES
UNSECURE
ERROR ADDR REG
xD01B37BA
CPU MEM READ ECC
PHYSICAL ERROR ADDR
x006CDEE8
CHECK SYNDROME
x00108884
SYND BITS x4
SINGLE BIT ERROR
CHECK BITS x8
MODULE NUM. x0
ERROR COUNT 1.
INVALID PC MEMINTR
----- ADDITIONAL INFO -----
CONTROLLER NO.
1.
ERRS ON THIS ADDR
1.
Troubleshooting Tools
3–11
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...