Table D-13.
FPU Test Error Codes
Error Code
Meaning
1
Values did not match. Value should be 00000000.
2
Values did not match. Value should be 55555555.
3
Values did not match. Value should be AAAAAAAA.
4
Values did not match. Value should be FFFFFFFF.
5
Least-significant bit failed when the system was converting
doubleword to word (CVT D. W.).
6
Most-significant bit failed when the system was converting
doubleword to word (CVT D. W.).
7
Double miscompare occurred.
8
Double miscompare occurred.
9
Convert float-double. Value should be 55555555.
10
FPU CSR double error occurred.
11
Single miscompare occurred.
12
Single miscompare occurred.
13
Convert float-double. Value should be 55555555.
14
FPU CSR single error occurred. Value should be 00000000.
15
Single division failed. Value should be 00005555.
16
Single multiplication failed.
17
Double multiplication failed.
18
Double division failed.
19
Conversion error occurred. Pattern readback did not match.
20
FPU interrupt was pending when it should not have been.
21
FPU did not trap on overflow exception.
22
FPU did not signal fault to CPU.
D–22
Test Commands and Messages
Summary of Contents for DECstation 5000 Model 100 Series
Page 24: ...ation DECsystem 5000 Model 200 Hardware 1 5...
Page 39: ...WSE2M050 W 359 Hz 50 60 A 7 9 4 2 V 100 120 220 240 nstalling a serial number plate...
Page 85: ...WSE2M018 are on a new system module Basic Hardware 5 7...
Page 100: ...WSE2M051 power cord connections...
Page 102: ...WSE2M045 power supply fan assembly connection...
Page 112: ...Figure B 1 DECstation 5000 Unit Assembly B 2 Recommended Spares List...