Table F-22 (Cont.).
Cache Isolate Test Error Codes
Error Code
Description
10
Reading 55555555 pattern returned a data miscompare.
11
Test failed reading AAAAAAAA pattern.
12
Reading AAAAAAAA pattern returned a cache parity error.
13
Reading AAAAAAAA pattern returned a cache miss error.
14
Reading AAAAAAAA pattern returned a data miscompare.
15
Failure occurred reading data address pattern.
16
Reading data address pattern returned a cache parity error.
17
Reading data address pattern returned a parity error.
18
Reading data address pattern returned a miscompare error.
Overtemp Detect Test
The overtemp detect test checks the overtemperature bit in
CSR. To run the overtemp detect test, type t f90 and press
Return.
Overtemp detect test error messages
The system returns error code 1 if the overtemperature bit fails
the overtemp detect test.
F–18
Test Commands and Messages Produced by Version PDE3 ROM Chips