4.10. USING
COUNTERS
The
X
next to the
V
on the setting-value command indicates the counter
to preserve its recycling flag: If the letters
R
or
C
were used instead of
X
,
the counter will not only change its value but its recycling configuration too.
A counter value may be consulted at any time.
Use the
V
command in query
form (
>
QGC00V
<
)
.
A counter configuration may include an optional
delta
parameter to make
the counter value increment only when the counting variable reaches the
delta
. This is useful for counting not only seconds but minutes, hours, etc
or for distance counter to count meters, kilometers, tens of kilometers, etc.
COUNTERS-type counters only count on a command basis, meaning that
count when told to do so.
Use the
I
command.
As with any TAIP command, counters manipulation/configuration can be
included on an event’s action, so counters can be used to start timers or
distance counts on an automatic basis when a defined situation occurs. An
example of such configuration can be found on the
Scenarios and Examples
sections. With the same method, counters can be used to count the number
of occurrences of an event.
For more examples and information on counters see the
GC
command on the
94
Summary of Contents for Antares SB
Page 1: ......
Page 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Page 37: ...2 1 POWER SUPPLY 35...
Page 38: ...2 1 POWER SUPPLY 36...
Page 42: ...2 5 CONNECTION DIAGRAMS 40...
Page 141: ...6 Unit s TAIP reference...
Page 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Page 228: ......
Page 229: ......