6.42. (XAIO) INPUT, OUTPUTS CONSULT
6.42
(XAIO) Input, Outputs consult
Qualifiers
:
Q
,
R
This message is used to consult the actual state of inputs and outputs.
;XABCD;IEFHJ;GKLM
Chars
Item
Format
Value
Meaning
1
Out 4
A
flag
State of Output 4 (1=active, 0=inactive).
1
Out 3
B
flag
State of Output 3.
1
Out 2
C
flag
State of Output 2.
1
Out 1
D
flag
State of Output 1.
1
Input 4
E
flag
State of Input 4.
1
Input 3
F
flag
State of Input 3.
1
Input 2
H
flag
State of Input 2.
1
Input 1
J
flag
State of Input 1.
1
Ignition
K
flag
State of vehicle ignition.
1
Power
L
flag
State of main power source.
1
12/24v
M
flag
State of main power source 12/24voltage detec-
tor.