6.49. (XAPM) POWER MANAGEMENT
(*) When going to sleep immediately using the ’I’ qualifier the saving mode
is not preserved. i.e. after the unit wakes up the unit ends the power saving
mode.
6.49.1
Examples
Activate the power saving mode. Only the vehicle’s ignition may awake the
1
unit, and when awaken, the unit must remain up for 20 minutes:
>
SXAPMA000000010000020m
<
Activate the power saving mode. Any input but the 24v/12v detector may
2
awake the unit, and the unit has to awake every 2 hours. Use default values
for the rest.
>
SXAPMA000001011111DDDDDDDD002h
<
To configure the unit to go to sleep mode any time the external power
3
is removed and to go back to normal mode when the power is connected
again:
1. Create an event triggered when the power signal (F13) goes low that
activates the Power Saving mode; making sure the Power input is in-
cluded on the signals to be monitored while on sleep state:
>
SED00SV0;F13-;ACT=SXAPMA
<
No input mask specified, so any input, particularly the power de-
tector will drive the unit back to normal mode.
2. Create an event triggered when the power signal goes high that deac-
tivates the power saving mode:
>
SED01SV0;F13+;ACT=SXAPME
<
Having this configuration the unit will go to sleep mode 2 minutes
after disconnecting the primary power source.
208
Summary of Contents for Antares SB
Page 1: ......
Page 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Page 37: ...2 1 POWER SUPPLY 35...
Page 38: ...2 1 POWER SUPPLY 36...
Page 42: ...2 5 CONNECTION DIAGRAMS 40...
Page 141: ...6 Unit s TAIP reference...
Page 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Page 228: ......
Page 229: ......