6.63. ERRORS LIST
ID
Description
00
Unrecognized command
02
The message is not delimited by
>
and/or
<
03
ID miss match on incoming postfix “
;ID=
”
04
KY miss match on incoming postfix “
;KY=
”
06
Not a valid set message.
07
Missing parameter.
08
TAIP console is restricted for this DP. See the locking parameters on the
XADP
message.
09
Queries resulting on multiple answers are not supported over the air.
10
Invalid Speed Threshold query. See the
GS
message.
11
Invalid Time Window query. See the
GT
message.
12
Invalid Time and Distance query. See the
TD
message.
15
Invalid Region query. See the
GR
message.
16
Invalid Event query. See the
ED
message.
17
Invalid Destination Address query. See the
DA
message.
18
Invalid Destination Point query. See the
XADP
message.
19
Invalid index.
20
Message can not be used with
D
qualifier. See the Introduction Chapter.
21
SRT;ALL
can only be used locally. Use the serial port.
22
The unit is restarting and it can not process any command.
23
Minimum time/date can not be ahead of Maximum time/date on a Time Window.
24
Invalid characters on string parameter.
25
Invalid vehicle ID. See the
ID
message.
26
PIN can only be modified locally. Use the serial port.
27
APN can not be changed via IP communication. Use serial port or SMS messages.
28
Unrecognized RF parameter. See the
RF
message.
29
RF parameter longitude exceeded. See the
RF
message.
30
Set messages are locked for the serial port. See the
XALL
message.
31
Wrong unlocking code. See the
XALL
message.
32
Invalid MDT PAD Size. See the
MT
message.
33
Invalid
MT
format. See the
MT
message.
34
Invalid MDT PAD Timeout. See the
MT
message.
35
Event definition space exeeded. See the
ED
message. Try dividing a long event into several cascading
events using
event signals
and
user signals
.
36
Event sense
missing on event definition. See the
ED
message.
37
Non-existent signal on event definition. See the
ED
message and Signals Chapter.
38
PAD1 or PAD2 must differ from PAD escape and PAD entry. See the
MT
message.
39
Invalid KY set format.
40
The signal can not be changed by user. See the
SS
message. The signal depends on the units’ situation
and so it can not be arbitrary modified. Only
user signals
and
outputs
can be manipulated directly by
the user.
41
An input can not be modified. Only outputs may be modified with the
SS
message.
42
Invalid signal index. See the Signals Chapter.
44
Invalid XAGA or XAGB query.
45
Wrong XAGA or XAGB parameter.
The table continues on the next page.
223
Summary of Contents for Antares SB
Page 1: ......
Page 2: ...Antares SB TM GSM User s Manual FW 5 21 Digital Communications Technologies April 15 2008...
Page 37: ...2 1 POWER SUPPLY 35...
Page 38: ...2 1 POWER SUPPLY 36...
Page 42: ...2 5 CONNECTION DIAGRAMS 40...
Page 141: ...6 Unit s TAIP reference...
Page 191: ...6 32 XADM DIAGNOSTIC MESSAGE 189...
Page 228: ......
Page 229: ......