310
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
C o n f i g u r i n g t h e E F 2 8 0 0
To enable or disable the alarm:
1.
From the System Menu, select
Configuration Menu
and press
<
Enter>. The Configuration Menu displays.
2.
Select
Alarm Mute
and press
<
Enter>.
The Alarm Mute menu
displays
(Figure 168)
. The current setting is marked with an * next
to it.
3.
Select the option you want and press
<
Enter>.
12V voltage
• Warning: 12 V -20% to -
10% and +10% to +20%
• Shutdown: 12 V <-20% and
>+20%
• Same as above for the VCC voltage.
2.5 V voltage
• Warning: 2.5 V -10% to -8%
and +8% to +10%
• Shutdown: N/A
• Same as above for the VCC voltage.
Figure 167.
.
Alarm thresholds
Alarm threshold
What to do when the alarm sounds
Figure 168. Alarm Mute Menu