152
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
T r o u b l e s h o o t i n g a n d P r o b l e m S o l v i n g
10.5
Drive Carrier Module Faults
Disk drive status is monitored by a green LED and an amber LED
mounted on the front of each Drive Carrier Module, providing the
following indications:
Drive activity - LED may be off for a length of time during power up.
10.5.1
Dummy Carrier Modules
Dummy Carrier modules must be fitted to all unused drive bays to
maintain balanced air flow.
10.5.2
Auto Start Failure
Unless otherwise selected at installation time, all drives in the
enclosure should automatically start their motors after power is
applied. If this has not occurred there is a power problem (An alarm and
power fault indication would normally be active).
N
OTE
:
The SYSTEM LED will flash green/amber.
State
Green
Amber
No drive fitted
Off
Off
Drive Power ON
On
Off
Drive Activity
Flashes
Off
Drive Fault
On
On
Summary of Contents for EF2800
Page 1: ...EF2800 Fibre Channel RAID System User Guide ...
Page 2: ...V 1 0 EF2800 Fibre Channel RAID Storage System User Guide DataDirect Networks ...
Page 5: ...iv This page intentionally left blank ...
Page 13: ...This page intentionally left blank xii ...
Page 37: ...This page intentionally left blank 14 ...
Page 65: ...This page intentionally left blank 42 ...
Page 79: ...This page intentionally left blank 56 ...
Page 201: ...This page intentionally left blank 178 ...
Page 215: ...This page intentionally left blank 192 ...
Page 227: ...This page intentionally left blank 204 ...
Page 305: ...This page intentionally left blank 282 ...
Page 343: ...This page intentionally left blank 320 ...