1.4.14 PC Software Tools
PC Software - MCT 10
All drives are equipped with a serial communication port. We provide a PC tool for communication between PC and frequency converter, VLT Motion
Control Tool MCT 10 Set-up Software.
MCT 10 Setup Software
MCT 10 has been designed as an easy to use interactive tool for setting parameters in our frequency converters.
The MCT 10 Set-up Software will be useful for:
•
Planning a communication network off-line. MCT 10 contains a complete frequency converter database
•
Commissioning frequency converters on line
•
Saving settings for all frequency converters
•
Replacing a drive in a network
•
Expanding an existing network
•
Future developed drives will be supported
MCT 10 Setup Software support Profibus DP-V1 via a Master class 2 connection. It makes it possible to on line read/write parameters in a frequency
converter via the Profibus network. This will eliminate the need for an extra communication network.
The MCT 10 Setup Software Modules
The following modules are included in the software package:
MCT 10 Setup Software
Setting parameters
Copy to and from frequency converters
Documentation and print out of parameter settings incl. diagrams
Ordering number:
Please order your CD containing MCT 10 Set-up Software using code number 130B1000.
1.4.15 Accessories
Type
Description
Ordering no.
LCP2 control unit
Alfanumeric display for programming the frequency converter.
175N0131
Cable for LCP2 control unit
Preconfectioned cable to be used between frequency converter and LCP2.
175N0162
LCP2 remote-mounting kit
Kit for permanent mounting of the LCP2 in an enclosure (incl. 3 m cable, excl. LCP2)
175N0160
LOP (Local Operation Pad)
LOP can be used for setting the reference
and start/stop via the control terminals
175N0128
Motor adaption plate
Aluminium plate with holes drilled to fit the FCD box. Must be fitted locally for the actual
motor. Plate for adapting to non Danfoss Bauer motors
175N2115
Venting Membrane
Membrane preventing water build-up due to condensation inside enclosures.
175N2116
Plug kit for LCP2
The installation box can be mounted with or without a sealed connector (IP66) to connect
the common display LCP2 (code DC). The connector can be ordered separately (Not for
single sided installation boxes).
175N2118
Motor star terminal
Six wires must be either star- or delta-connected to supply an AC motor. Delta connection
is possible in the standard motor terminal. Star connection requires a separate terminal.
175N2119
Installation kit
Installation kit for mounting in panels
175N2207
5 pole M12 plug for DeviceNet
The plug, micro type, M12 can be mounted into the gland holes of the installation box.
The plug can also be used for other purposes such as connection of sensors.
175N2279
Viton Gasket for FCD 303-315
With this gasket the FCD can be used in painting shops in e.g. the automotive industry.
175N2431
Viton Gasket for FCD 322-335
With this gasket the FCD can be used in painting shops in e.g. the automotive industry.
175N2450
Data Cable for PC communication
Connects a converter (e.g. USB) to the LCP2 connector.
175N2491
PCB Terminal
Terminal for 24 V distribution
175N2550
PE ext. terminal
Stainless steel
175N2703
2m drop cable for DeviceNet
The cable can be mounted inside the terminal box, and connects to the DeviceNet trunk
line via a micro connector (M12).
195N3113
5 pole M12 plug for AS-interface
The plug, M12, can be mounted into the gland holes of the installation box.
175N2281
1 The Decentral Concept
VLT
®
Decentral FCD 300 Design Guide
22
MG.90.S1.02 - VLT
®
is a registered Danfoss trademark
1