PNU # Parameterdescription
Factory setting
Changes during op-
eration
4-setup
Conv.
index
Data
type
500
Address
1
Yes
No
0
5
501
Baudrate
9600 Baud
Yes
No
0
5
502
Coasting stop
Logic or
Yes
Yes
0
5
503
Quick stop
Logic or
Yes
Yes
0
5
504
DC brake
Logic or
Yes
Yes
0
5
505
Start
Logic or
Yes
Yes
0
5
506
Reversing
Logic or
Yes
Yes
0
5
507
Selection of Setup
Logic or
Yes
Yes
0
5
508
Selection of preset ref.
Logic or
Yes
Yes
0
5
509
Bus jog 1
10.0 Hz
Yes
Yes
-1
6
510
Bus jog 2
10.0 Hz
Yes
Yes
-1
6
512
Telegram profile
FC protocol
No
Yes
0
5
513
Bus time interval
1 sec.
Yes
Yes
0
5
514
Bus time interval function
Off
Yes
Yes
0
5
515
Data readout: Reference %
No
No
-1
3
516
Data readout: Reference [unit]
No
No
-3
4
517
Data readout: Feedback [unit]
No
No
-3
4
518
Data readout: Frequency
No
No
-1
3
519
Data readout: Frequency x scaling
No
No
-1
3
520
Data readout: Motor current
No
No
-2
7
521
Data readout: Torque
No
No
-1
3
522
Data readout: Power [kW]
No
No
1
7
523
Data readout: Power [HP]
No
No
-2
7
524
Data readout: Motor voltage [V]
No
No
-1
6
525
Data readout: DC Link voltage
No
No
0
6
526
Data readout: Motor thermal load
No
No
0
5
527
Data readout: Inverter thermal load
No
No
0
5
528
Data readout: Digital input
No
No
0
5
529
Data readout: Analogue input, term. 53
No
No
-1
5
531
Data readout: Analogue input, term. 60
No
No
-4
5
532
Data readout: Pulse input, term. 33
No
No
-1
7
533
Data readout: External reference
No
No
-1
6
534
Data readout: Status word
No
No
0
6
537
Data readout: Inverter temperature
No
No
0
5
538
Data readout: Alarm word
No
No
0
7
539
Data readout: Control word
No
No
0
6
540
Data readout: Warning word
No
No
0
7
541
Data readout: Extended status word
No
No
0
7
544
Data readout: Pulse count
No
No
0
7
545
Data readout: Pulse input, term. 29
No
No
-1
7
PNU #
Parameterdescription
Factory setting
Changes during
operation
4-setup
Conv.
index
Data
type
600
Operating hours
No
No
73
7
601
Hours run
No
No
73
7
602
kWh counter
No
No
2
7
603
Number of cut ins
No
No
0
6
604
Number of overtemperatures
No
No
0
6
605
Number of overvoltages
No
No
0
6
615
Fault log: Error code
No
No
0
5
616
Fault log: Time
No
No
0
7
617
Fault log: Value
No
No
0
3
618
Reset of kWh counter
No reset
Yes
No
0
7
619
Reset of running hours counter
No reset
Yes
No
0
5
620
Operation mode
Normal operation
Yes
No
0
5
621
Nameplate: Unit type
No
No
0
9
624
Nameplate: Software version
No
No
0
9
625
Nameplate: LCP identification no.
No
No
0
9
626
Nameplate: Database identification no.
No
No
-2
9
627
Nameplate: Power parts version
No
No
0
9
628
Nameplate: Application option type
No
No
0
9
630
Nameplate: Communication option type
No
No
0
9
632
Nameplate: BMC software identification
No
No
0
9
634
Nameplate: Unit identification for communication
No
No
0
9
635
Nameplate: Software parts no.
No
No
0
9
640
Software version
No
No
-2
6
641
BMC software identification
No
No
-2
6
642
Power card identification
No
No
-2
6
678
Configure Control Card
Depends on unit type
No
No
0
5
VLT
®
Decentral FCD 300 Design Guide
5 All About FCD 300
MG.90.S1.02 - VLT
®
is a registered Danfoss trademark
145
5