515-545 Data readout
Value:
Par.
no.
Description
Display text
Unit
515
Res. reference
(REFERENCE %)
%
516
Res. reference [Unit]
(REFERENCE [UNIT])
Hz, rpm
517
Feedback [Unit]
(FEEDBACK [UNIT])
Par. 416
518
Frequency
(FREQUENCY)
Hz
519
Frequency x scale
(FREQUENCY X SCALE)
Hz
520
Motor current
(MOTOR CURRENT)
Amp
521
Torque
(TORQUE)
%
522
Power[kW]
(POWER (KW))
kW
523
Power[HP]
(POWER (HP))
HP
524
Motor voltage
(MOTOR VOLTAGE)
V
525
DC-link voltage
(DC LINK VOLTAGE)
V
526
Thermal load motor
(MOTOR THERMAL)
%
527
Thermal load inverter
(INV. THERMAL)
%
528
Digital input
(DIGITAL INPUT)
Bin
529
Term.53, analogue input
(ANALOG INPUT 53)
V
531
Term.60, analogue input
(ANALOG INPUT 60)
mA
532
Term. 33, pulse input
(PULSE INPUT 33)
Hz
533
External ref.
(EXT. REF.%)
%
534
Status word, Hex
(STATUS WORD)
Hex
537
Inverter temperature
(INVERTER TEMP.)
°C
538
Alarm word
(ALARM WORD)
Hex
539
Control word
(CONTROL WORD)
Hex
540
Warning word
(WARN. WORD)
Hex
541
Extended status word
(EXT. STATUS WORD)
Hex
544
Pulse count
(PULSE COUNT)
545
Term. 29, pulse input
(PULSE INPUT 29)
Hz
Function:
These parameters can be read out via the serial communication port and
the LCP display. See also parameters 009-012
Display readout
.
NB!
Parameters 515-541 can only be read out via the serial
communication port.
Description of choice:
Resulting reference %, parameter 515:
Gives the resulting reference as a percentage in the range from Minimum
reference, Ref
MIN
to Maximum reference, Ref
MAX
. See also
Dealing with
references
.
Resulting reference [unit], parameter 516:
Gives the resulting reference in Hz in Open loop (parameter 100). In a
closed loop the reference unit is selected in parameter 416
Process
units
.
Feedback [unit], parameter 517:
Gives the resulting feedback value with the unit/scaling selected in pa-
rameters 414, 415 and 416. See also dealing with feedback.
Frequency [Hz], parameter 518:
Gives the output frequency from the frequency converter.
Frequency x scaling [-], parameter 519:
corresponds to the present output frequency f
M
multiplied by the factor
preset in parameter 008
Display scaling of output frequency
.
Motor current [A], parameter 520:
Gives the motor's phase current measured as an effective value.
Torque [Nm], parameter 521:
Gives the motor's present load in relation to the motor's rated torque.
Power [kW], parameter 522:
Gives the present power absorbed by the motor in kW.
Power [HP], parameter 523:
Gives the present power absorbed by the motor in HP.
Motor voltage, parameter 524:
Gives the voltage being supplied to the motor.
DC link voltage, parameter 525:
Gives the intermediate circuit voltage in the frequency converter.
Thermal load, motor [%], parameter 526:
Gives the calculated/estimated thermal load on the motor. 100% is the
cut-out limit. See also parameter 128
Thermal motor protection
.
Thermal load INV [%], parameter 527:
Gives the calculated/estimated thermal load on the frequency converter.
100% is the cut-out limit.
Digital input, parameter 528:
Gives the signal status from the 5 digital inputs (18, 19, 27, 29 and 33).
Input 18 corresponds to the bit on the extreme left. '0' = no signal, '1' =
connected signal.
Terminal 53 analogue input [V], parameter 529:
Gives the voltage value for the signal on terminal 53.
Terminal 60 analogue input [mA], parameter 531:
Gives the present value for the signal on terminal 60.
Pulse input 33[Hz], parameter 532:
Gives a pulse frequency in Hz connected to terminal 33.
External reference, parameter 533:
Gives the sum of external references as a percentage (sum of analogue/
pulse/serial communication) in the range from Minimum reference,
Ref
MIN
to Maximum reference, Ref
MAX
.
Status word, parameter 534:
Gives the present status word for the frequency converter in Hex. See
Serial communication for the VLT 2800.
Inverter temperature, parameter 537:
Gives the present inverter temperature on the frequency converter. The
cut-out limit is 90-100 °C, with cut back in at 70 ± 5 °C.
Alarm word, parameter 538:
Gives in Hex code which alarm is on the frequency converter. See
Warn-
ing word, extended status word and alarm word.
Control word, parameter 539:
Gives the present control word on the frequency converter in Hex. See
Serial communication for the FCD 300.
VLT
®
Decentral FCD 300 Design Guide
4 Programming
MG.90.S1.02 - VLT
®
is a registered Danfoss trademark
113
4