ENGINEERING TOMORROW
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
n
fo
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Fault Detection
Algorithm - Steering
wheel activation
velocity threshold
P3122
U8
dRpm
Steering wheel angle velocity threshold used in the Fault Detection
Algorithm to detect the steering wheel activation
OEM
0
150
5
S
Fault Detection
Algorithm – min. wheel
angle movement
threshold
P3123
U8
IR
Minimum wheel angle difference necessary to observe in order to make the
Fault Detection Algorithm assume that the wheels are moving
OEM
0
200
50
S
Fault Detection
Algorithm – wheel angle
sensor delay
P3124
U8
x10mSec
Number of loops between samples that are being compared against next
parameter or WA motion determination
OEM
1
20
1
S
Fault Detection
Algorithm - Fault
confidence counter
decrease rate
P3125
U8
x10mSec
Rate at which the Fault Detection Algorithm confidence counter value
decreases if an error is no longer observed
OEM
1
10
1
S
Fault Detection
Algorithm - Fault
confidence counter
timeout
P3126
U16
x10mSec
Time period for which error shall be observed by FDA to report failure
OEM
0
2000
50
S
Fault Detection
Algorithm - Spool in left
position range offset
P3128
S16
x10u Meter
Distance from closed loop dead-band to check if spool in left side
OEM
-200
200
0
S
Fault Detection
Algorithm - Spool in
right position range
offset
P3130
S16
x10u Meter
Distance from closed loop dead-band to check if spool in right side
OEM
-200
200
0
S
Fault Detection
Algorithm - Safe state
upon a failure detection
P3132
U8
-
FDA safe state trigger Enable/Disable after failure detection.
Valid Values: 0 (DISABLE); 255 (ENABLE)
Warning
DISABLE should only be used when diagnosis of the wheel angle
sensor and SASA failure modes are ensured by anther monitoring
function or when getting initial data for FDA tuning
OEM
0
255
0
S
Fault Detection
Algorithm - Backlash
region
P3133
U8
dDeg
Backlash limit to use in the backlash filter in the FDA control algorithm
exclusively
Resolution: 1dDeg = 0.1Deg
OEM
0
200
5
S
Fault Detection
Algorithm - Vehicle
speed threshold for
EHPS
P3134
U8
km/h
Will disable the FDA and spool monitoring if speed of the vehicle goes
below this value. Should only be changed if EHPS/OSPE system is
underpowered, hence the system does not have enough pressure to move
the wheels (normally when vehicle is not moving)
OEM
0
10
0
S
Table 60
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...