© Danfoss | August 2018
AQ00000211 |
153
ENGINEERING TOMORROW
17.4.6
Peripherals Config
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fe
ty
c
rit
ic
a
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
GPS present
P3237
U8
-
Auto-guidance controller present/Not Present
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM
0
255
255
GPS2 present
P3238
U8
-
A second auto-guidance controller present/Not Present
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM
0
255
255
AUX present
P3239
U8
-
AUX device Present/Not Present
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM
0
255
0
AUX type
P3240
U8
-
Aux device is mini steering wheel or Joystick
Valid Values: 0 (Open Loop Joystick); 1 (Closed Loop Joystick); 2 (mini
steering wheel); 3 (Analogue Joystick);20 (Elobau joystick)
OEM
0
20
2
Road switch present
(connected to AD3)
P3241
U8
-
Specifies whether the road switch is or is not present, i.e. connected to the
analogue input AD3
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM
0
255
255
S
Road switch resistance
check
P3242
U8
-
Road Switch Resistance check Enable/Disable
Valid Values: 0 (DISABLE); 255 (ENABLE)
OEM
0
255
0
S
Max COV connection
test current
P3243
U8
mAmp
The max. current allowed to be observed during the cut-off solenoid valve
connection test.
OEM
10
255
100
S
WAS interface
P3244
U8
-
Wheel Angle Sensor Interface Type
Valid Values: 0 (ANALOGUE); 1 (CAN); 2 (NONE)
OEM
0
2
0
Redundant WAS present
P3245
U8
-
Redundant Wheel Angle Sensor Present/Not Present
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM
0
255
255
S
Voltage compensation
for Primary analogue
sensor
P3246
U8
-
Supply voltage compensation Enable/Disable for processing primary
Analogue sensor signal
Valid Values: 0 (DISABLE); 255 (ENABLE)
OEM
0
255
255
Voltage compensation
for Redundant analogue
sensor
P3247
U8
-
Supply voltage compensation Enable/Disable for processing redundant
analogue sensor signal
Valid Values: 0 (DISABLE); 255 (ENABLE)
OEM
0
255
255
Generation of 5V sensor
supply voltage (Deutsch
connector pin 11)
P3248
U8
-
Sensor Supply Test. Disable/enable the internal 5V supply on the PVED-
CLS’ pin 11.
Valid Values: 0 (Enable); 1 (Disable)
Note: Should be kept at Enable (P3248 set to 0) all time
OEM
0
1
0
AD low pass filter cut-
off frequency
P3249
U8
dHz
5V sensor, AD1 and AD2 filter cut-off frequency
Resolution: 1 dHz = 0.1 Hz
OEM
5
200
100
Max vehicle speed for
engaging auto-guidance
or AUX steering device
P3250
U8
km/h
Max vehicle speed at which a lower priority steering device can be engaged
OEM
0
100
15
S
Max vehicle speed for
steering program
changes
P3251
U8
km/h
Max vehicle speed at which a steering program for the selected device can
be changed
OEM
0
100
15
S
Lower vehicle speed
auto-guidance suspend
threshold
P3252
U8
x10m/h
Minimum vehicle speed below which spool movement is disabled when
auto-guidance steering is engaged.
Resolution: 1 x10m/h = 10 meter pr. hour
OEM
0
200
50
S
Safe state vehicle speed
threshold
P3253
U8
km/h
The vehicle speed at which the PVED-CLS shall enter the safe state
OEM
5
100
25
S
EH-Steering disengage
method
P3254
U8
-
EH-Steering disengage method
Valid values: 0 (SASA); 1 (IMD: Internally Monitored Disengage)
OEM
0
1
0
Table 69
Important
For the Peripherals sector some rules apply to P3072, P3241 & P3242. See list of rules in
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...