© Danfoss | August 2018
AQ00000211 |
73
ENGINEERING TOMORROW
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Primary analogue sensor
max left position
P3205
U16
mVolts
Primary analogue sensor voltage output for leftmost position
OEM, Dealer
0
6000
500
Primary analogue sensor
max right position
P3207
U16
mVolts
Primary analogue sensor voltage output for rightmost position
OEM, Dealer
0
6000
4500
Primary analogue sensor
neutral position
P3209
U16
mVolts
Primary analogue sensor voltage output for neutral position
OEM, Dealer
0
6000
2500
Redundant analogue
sensor max left position
P3211
U16
mVolts
Redundant analogue sensor voltage output for leftmost position
OEM, Dealer
0
6000
500
Redundant analogue
sensor max right
position
P3213
U16
mVolts
Redundant analogue sensor voltage output for rightmost position
OEM, Dealer
0
6000
4500
Redundant analogue
sensor neutral position
P3215
U16
mVolts
Redundant analogue sensor voltage output for neutral position
OEM, Dealer
0
6000
2500
5V sensor supply for
primary analogue sensor
during calibration
P3217
U16
mVolts
Measured Supply voltage during calibration of the primary analogue sensor
OEM, Dealer
4650
5350
5000
5V sensor supply for
redundant analogue
sensor during calibration
P3219
U16
mVolts
Measured Supply voltage during calibration of the redundant analogue
sensor
OEM, Dealer
4650
5350
5000
Automatically adjusted
cylinder stroke volume
(CAN WAS)
P3191
U16
ccm
Automatically adjusted cylinder stroke volume, for using CAN WAS,
found during WAS auto-calibration
OEM, Dealer
100
65535
65535
Automatically adjusted
maximum steer angle to
left side (CAN WAS)
P3193
U16
Deg
Automatically adjusted maximum steer angle to left side, for using CAN
WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Automatically adjusted
maximum steer angle to
right side (CAN WAS)
P3195
U16
Deg
Automatically adjusted maximum steer angle to right side, for using CAN
WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Automatically adjusted
cylinder stroke volume
(analogue WAS)
P3221
U16
ccm
Automatically adjusted cylinder stroke volume, for using analogue WAS,
found during WAS auto-calibration
OEM, Dealer
100
65535
65535
Automatically adjusted
maximum steer angle to
left side (analogue
WAS)
P3223
U16
Deg
Automatically adjusted maximum steer angle to left side, for using
analogue WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Automatically adjusted
maximum steer angle to
right side (analogue
WAS)
P3225
U16
Deg
Automatically adjusted maximum steer angle to right side, for using
analogue WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Table 31
Or
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
WAS max left position
(CAN)
P3185
U16
mVolts
Wheel angle sensor voltage output for leftmost position over CAN
OEM, Dealer
0
5000
500
WAS max right position
(CAN)
P3187
U16
mVolts
Wheel angle sensor voltage output for rightmost position over CAN
OEM, Dealer
0
5000
4500
WAS neutral position
(CAN)
P3189
U16
mVolts
Wheel angle sensor voltage output for neutral position over CAN
OEM, Dealer
0
5000
2500
Table 32
Important
If WAS interface is selected as NONE then WAS auto-calibration cannot be performed.
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...