9.5.3
Execute Analogue Joystick auto-calibration from the PLUS+1 SERVICE TOOL
In the navigation pane, find “Parameter Pages”
“Auto-Calibration”
“Joystick Calibration”
Figure 32
Press “Goto Joystick Calibration Mode”. Now the leftmost, rightmost and neutral position can be captured, simply by
steer the Joystick fully left, fully right and back to neutral and press the capture buttons (Capture L, Capture N and Capture
R) respectively. It does not matter in which sequence this is done. Danfoss recommends to capture neutral position while
driving the vehicle slowly, aiming at a spot far away.