© Danfoss | August 2018
AQ00000211 |
177
ENGINEERING TOMORROW
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Max spool position, left
P3162
S16
x10u Meter
Spool left most position
OEM, Dealer
-1000
-300
-420
Max spool position,
right
P3164
S16
x10u Meter
Spool right most position
OEM, Dealer
300
1000
420
Closed loop dead-band
edge, left
P3166
S16
x10u Meter
Spool closed loop dead-band edge, Left
OEM, Dealer
-300
0
-105
Closed loop dead-band
edge, right
P3168
S16
x10u Meter
Spool closed loop dead-band edge, Right
OEM, Dealer
0
300
105
Open loop dead-band
edge offset
P3170
S16
x10u Meter
Spool open loop dead-band offset
OEM, Dealer
0
150
25
Table 88
17.6.5.2
Spool calibration procedure
Determining the closed loop dead-bands
The principle in this calibration procedure is to determine the closed-loop mode dead-bands first. The closed-loop dead-
bands are defined as the slowest possible steered wheel movement speed that is used for controlling the smallest possible
wheel angle position error (proportional control). Once the closed-loop dead-bands are determined (P3166 and P3168),
the open-loop dead-bands are derived by subtracting an off-set (P3170) from the respective closed-loop mode dead-band
positions (P1 and P2 from Figure 68)
The following calibration procedure is based on balancing the time it takes to move between two fixed wheel angles by
adjusting two experimental spool position set-point values.
Important
The criteria which shall be evaluated for valve calibration are:
•
The times to move from left to right and vice versa are equal (symmetry measure)
•
The time to move from left to right and vice versa is sufficiently slow (minimum flow)
These above times depends on e.g. vehicle geometry
,
steering type, cylinder stroke volume, wheel angle sensor
calibration, valve capacity and requirements on minimum correction flows for closed-loop mode operation.
Determining the open loop dead-bands
When the closed-loop mode dead-bands are found, the open-loop dead-bands values (P1 and P2 from Figure 68) are set
by subtracting an offset (defined by parameter P3170) from the closed-loop dead-band values.
The criteria for having derived good open-loop dead-bands are:
•
The valve shall not steer out any flow and therefore the steered wheel shall not exhibit movement jitter when no
steering activity takes place
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...