© Danfoss | August 2018
AQ00000211 |
151
ENGINEERING TOMORROW
17.4.3
Valve Calibration
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Max spool position, left
P3162
S16
x10u Meter
Spool left most position
OEM, Dealer
-1000
-300
-420
Max spool position, right
P3164
S16
x10u Meter
Spool right most position
OEM, Dealer
300
1000
420
Closed loop dead-band edge, left
P3166
S16
x10u Meter
Spool closed loop dead-band edge, Left
OEM, Dealer
-300
0
-105
Closed loop dead-band edge, right
P3168
S16
x10u Meter
Spool closed loop dead-band edge, Right
OEM, Dealer
0
300
105
Open loop dead-band edge offset
P3170
S16
x10u Meter
Spool open loop dead-band offset
OEM, Dealer
0
150
25
Table 66
17.4.4
CAN WAS Calibration Data
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
WAS max left position
(CAN)
P3185
U16
mVolts
Wheel angle sensor voltage output for leftmost position over CAN
OEM, Dealer
0
5000
500
WAS max right position
(CAN)
P3187
U16
mVolts
Wheel angle sensor voltage output for rightmost position over CAN
OEM, Dealer
0
5000
4500
WAS neutral position
(CAN)
P3189
U16
mVolts
Wheel angle sensor voltage output for neutral position over CAN
OEM, Dealer
0
5000
2500
Automatically adjusted
cylinder stroke volume
(CAN WAS)
P3191
U16
ccm
Automatically adjusted cylinder stroke volume, for using CAN WAS,
found during WAS auto-calibration
OEM, Dealer
100
65535
65535
Automatically adjusted
maximum steer angle to
left side (CAN WAS)
P3193
U16
Deg
Automatically adjusted maximum steer angle to left side, for using CAN
WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Automatically adjusted
maximum steer angle to
right side (CAN WAS)
P3195
U16
Deg
Automatically adjusted maximum steer angle to right side, for using CAN
WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Table 67
Important
For CAN WAS calibration data sector, the following rules apply:
P3185 < P3187 < P3189 OR P3185 > P3187 > P3189
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...