© Danfoss | August 2018
AQ00000211 |
145
ENGINEERING TOMORROW
Category
SPN
Signal Name
Failure mode
FMI
Severity
Possible root cause(s)
Software
520229
Soft error
Soft error detected
31 - Condition exists
Severe
Internal failure
Software
520213
SPI Communication
Connection loss
11 - Unknown root-cause
Severe
Internal failure
SPI message queue full
2 - Data erratic, intermittent or
incorrect
Severe
Internal failure
Software
1557
RAM test
RAM-code test fails
12 - Bad intelligent device or
component
Severe
Internal failure
Software
520579
EEPROM VPS data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520232
EEPROM Hydraulic config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520233
EEPROM SEHS FDA
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520234
EEPROM Valve calibration
data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520235
EEPROM CAN WAS
Calibration data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Illegal parameter combinations – see section 17.4.4
3.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520236
EEPROM Analogue Sensor
Calibration data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Illegal parameter combinations – see section 17.4.5
3.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520237
EEPROM Peripherals config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Illegal parameter combinations – see section 17.4.6
3.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520238
EEPROM SEHS Protocol data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520239
EEPROM Internal monitoring
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520241
EEPROM Vehicle geometry
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520242
EEPROM GPS config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Illegal parameter combinations – see section 12
3.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520243
EEPROM STW config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Illegal parameter combinations – see section 10
3.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520244
EEPROM AUX config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Illegal parameter combinations – see section 11
3.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520245
EEPROM Auto-Calibration
config sector
Parameter value out of
range/Incorrect configuration
of EEPROM data
2 - Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14 - Special instructions
Severe
1.
Incorrect Approval CRC
Software
520246
Invalid sensor configuration
Invalid sensor configuration
31 – Condition exists
Severe
If parameter settings are not done as per section 6.1.1
Software
299005
Software Initialization
Fault in software
configuration or initialization
process
11 - Unknown root-cause
Severe
Internal failure
Software
299004
Division by zero
Division by zero
11 - Unknown root-cause
Severe
Internal failure
Software
628
Flash test
Flash test failure
12 - Bad intelligent device or
component
Severe
Internal failure
Software
299002
Variable truncation
Variable truncation
11 - Unknown root-cause
Severe
Internal failure
Software
299001
I2C communication
I2C communication failure
12 - Bad intelligent device or
component
Severe
Internal failure
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...