92 | © Danfoss | August 2018
AQ00000211
ENGINEERING TOMORROW
Figure 45
If P3578 is set to 1000 IR, the mixing factor 100 % will be considered for calculation of adjusted flow set-point.
As per default, P3578 and P3580 are both set to 10. Having both parameters set to the same value cancel out any crossover
ramping. To enable the function, set P3578 and P3580 to a value between 0 and 1000 to indicate the crossover start (P3578)
and crossover stop (P3580).
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
STW anti-jerk function
P3571
U8
-
Defines the type of the anti-jerk functionality to
use 0 for Anti Jerk type NONE and 1 for Anti Jerk type 1
OEM
0
1
0
STW relative set-point
change, out from spool
neutral position
P3572
U8
%
Relative set-point change allowed to apply when ramping the spool
position set-point out, i.e. further out from the spool neutral position [%]
OEM
0
100
5
STW relative set-point
change, in towards spool
neutral position
P3573
U8
%
Relative set-point change allowed to apply when ramping the spool
position set-point in, i.e. towards the spool neutral position [%]
OEM
0
100
5
STW absolute set-point
change, out from spool
neutral position
P3574
U16
IR
Set-point change allowed to apply when ramping the spool position set-
point out, i.e. further out from the spool neutral position
OEM
1
1000
15
STW absolute set-point
change, in towards spool
neutral position
P3576
U16
IR
Set-point change allowed to apply when ramping the spool position set-
point in, i.e. towards the spool neutral position
OEM
1
1000
10
STW anti-jerk cross-
over start point
P3578
U16
IR
STW Anti-jerk Cross-over start
OEM
0
1000
10
STW anti-jerk cross-
over stop point
P3580
U16
IR
STW Anti-jerk Cross-over stop
OEM
0
1000
10
STW anti-jerk low pass
filter cut-off frequency
P3582
U8
dHz
STW Anti-jerk low pass filter cut-off frequency
Resolution: 1 dHz = 0.1 Hz
OEM
5
200
100
STW in use - Velocity
threshold
P3583
U8
dRpm
Steering wheel velocity threshold
OEM
1
100
5
S
STW in use - Angle
threshold
P3584
U8
Deg
Steering wheel position change threshold, from last detected position at 0
RPM
OEM
0
45
10
S
Table 39
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...