Option List
SiENBE34-703
218
Appendix
3. Option List
3.1 Option List of Controllers
Operation Control System Optional Accessories
Note:
1. Installation box (No.8) is necessary for each adapter marked
H
.
2. Up to 2 adapters can be fixed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
5. Installation box (No. 8) is necessary for second adapter.
6. Installation box (No. 8) is necessary for each adapter.
7. This adapter is required when connecting with optional controller for centralized control.
8. BRC2A51 is also available.
Various PC Boards
System Configuration
Note:
Installation box for
H
adapter must be procured on site.
No.
Type
FXCQ-M8 FXFQ-P7 FXZQ-M8 FXKQ-MA
FXDQ-
NA • M • P FXUQ-MA FXSQ-M8 FXMQ-MA FXHQ-MA FXAQ-MA
FXLQ-MA
FXNQ-MA
Item
1
remote
control
Wireless
H/P
BRC7C62
BRC7E61W BRC7E61W
BRC4C61
BRC4C62
BRC7C528W
BRC4C62
BRC7E63W BRC7E618
BRC4C62
Wired
BRC1C62
2
Wired remote control with
weekly schedule timer
BRC1D61
3
Simplified remote control
—
Note 8
BRC2C51
—
Note 8
BRC2C51
—
Note 8
BRC2C51
4
remote control for hotel
use
—
BRC3A61
—
BRC3A61
—
BRC3A61
5
adapter for wiring
∗
KRP1B61
∗
KRP1B59
∗
KRP1B57
KRP1B61
∗
KRP1B56
—
KRP1B61
KRP1C3
—
KRP1B61
6-1
Wiring adapter for
electrical appendices (1)
∗
KRP2A61
∗
KRP2A62
KRP2A61
∗
KRP2A53
∗
KRP2A62
KRP2A61
∗
KRP2A62
∗
KRP2A61
KRP2A61
6-2
Wiring adapter for
electrical appendices (2)
∗
KRP4A51
∗
KRP4A53
KRP4A51
∗
KRP4A54
∗
KRP4A53
KRP4A51
∗
KRP4A52
∗
KRP4A51
KRP4A51
7
Remote sensor
KRCS01-1
—
KRCS01-1
8
Installation box for
adapter PCB
Note 2, 3
KRP1B96
Note 2, 3
KRP1D98
Note 4, 6
KRP1B101
—
Note 4, 6
KRP1B101
KRP1B97
Note 5
KRP4A91
—
Note 3
KRP1C93
Note 2, 3
KRP4A93
—
9
Central remote control
DCS302CA61
9-1
Electrical box with earth
terminal (3 blocks)
KJB311A
10
Unified ON/OFF controller
DCS301BA61
10-1 Electrical box with earth
terminal (2 blocks)
KJB212A
10-2
Noise filter (for
electromagnetic interface
use only)
KEK26-1
11
Schedule timer
DST301BA61
12
External control adapter
for outdoor unit (Must be
installed on indoor units)
∗
DTA104A61
∗
DTA104A62
DTA104A61
∗
DTA104A53
—
DTA104A61
∗
DTA104A62
∗
DTA104A61 DTA104A61
13
Interface adapter for
SkyAir-series
—
—
—
—
Note 7
DTA102A52
—
—
—
—
—
No.
Part name
Model No.
Function
1
adapter for wiring
KRP1B56
KRP1B57
KRP1B59
KRP1B61
KRP1C3
!
PC board when equipped with auxiliary electric heater in the indoor unit.
2
DIII-NET Expander adapter
DTA109A51
!
Up to 1024 units can be centrally controlled in 64 different groups.
!
Wiring restrictions (max. length: 1000m, total wiring length: 2000m, max. number of
branches: 16) apply to each adapter.
No.
Part name
Model No.
Function
1
Central remote control
DCS302CA61
!
Up to 64 groups of indoor units (128 units)can be connected, and ON/OFF, temperature
setting and monitoring can be accomplished individually or simultaneously. Connectable up
to “2” controllers in one system.
2
Unified ON/OFF controller
DCS301BA61
!
Up to 16 groups of indoor units (128 units) can be turned, ON/OFF individually or
simultaneously, and operation and malfunction can be displayed. Can be used in
combination with up to 8 controllers.
3
Schedule timer
DST301BA61
!
Programmed time weekly schedule can be controlled by unified control for up to 64 groups
of indoor units (128 units). Can turn units ON/OFF twice per day.
4
Unification adapter for computerized
control
H
DCS302A52
!
Interface between the central monitoring board and central control units
5
Interface adapter for SkyAir-series
H
DTA102A52
!
adapters required to connect products other than those of the VRV System to the high-
speed DIII-NET communication system adopted for the VRV System.
!
To use any of the above optional controllers, an appropriate adapter must be installed on
the product unit to be controlled.
6
Central control adapter kit
H
DTA107A55
7
Wiring adapter for other air-conditioner
H
DTA103A51
8
DIII-NET
Expander adapter
DTA109A51
!
Up to 1,024 units can be centrally controlled in 64 different groups.
!
Wiring restrictions (max. length : 1,000m, total wiring length : 2,000m, max. number of
branches : 16) apply to each adapter.
9
Mounting plate
KRP4A92
!
Fixing plate for DTA109A51
Summary of Contents for VRVIII-S
Page 1: ...SiENBE34 703 Basic Training Manual R 410A Heat Pump 50Hz Service Manual...
Page 11: ...Introduction SiENBE34 703 x...
Page 113: ...Field Setting SiENBE34 703 102 Test Operation...
Page 207: ...Troubleshooting by Indication on the Unified ON OFF Control SiENBE34 703 196 Troubleshooting...
Page 215: ...Wiring Diagrams SiENBE34 703 204 Appendix 2 3 Indoor Unit FXCQ20 25 32 63M8...
Page 216: ...SiENBE34 703 Wiring Diagrams Appendix 205 FXCQ40 50 80 125M8V3...
Page 217: ...Wiring Diagrams SiENBE34 703 206 Appendix FXFQ25 32 40 50 63 80 100 125P7VE...
Page 218: ...SiENBE34 703 Wiring Diagrams Appendix 207 FXZQ20 25 32 40 50M8V1...
Page 221: ...Wiring Diagrams SiENBE34 703 210 Appendix FXDQ20 25M8V3...
Page 222: ...SiENBE34 703 Wiring Diagrams Appendix 211 FXSQ20 25 32 40 50 63 80 100 125M8V3...
Page 232: ...SiENBE34 703 Option List Appendix 221...
Page 235: ...Example of Connection SiENBE34 703 224 Appendix...
Page 241: ...Method of Replacing the Inverter s Power Transistors Modules SiBE34 703 230 Appendix...
Page 261: ...RXYSQ4 5 6 P7Y1B SiENBE34 703 250 Removal Procedure...