![Daikin RXL25G2V1B Service Manual Download Page 45](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970045.webp)
SiENBE04-925_A
Main Functions
Function and Control
31
1.10 Inverter POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail
When POWERFUL button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
Ex.) : POWERFUL operation in cooling mode.
Operation mode
Fan speed
Target temperature
COOL
H tap + 50 rpm
18°C
DRY
Dry rotating speed + 50 rpm
Lowered by 2.5°C
HEAT
H tap + 50 rpm
31°C
FAN
H tap + 50 rpm
—
AUTO
Same as cooling / heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R7096)
Target temp.
Fan
50 rpm
18°C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes. also
in the remote control.
POWERFUL
ON
POWERFUL
OFF
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.
SIENBE04-925_A_FRONT.pdf 45
24/02/2011 13:53:52
Summary of Contents for RXL25G2V1B
Page 8: ...SiENBE04 925_A vi Table of Contents ...
Page 14: ...Introduction SiENBE04 925_A xii ...
Page 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Page 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Page 20: ...Specifications SiENBE04 925_A 6 Specifications ...