![Daikin RXL25G2V1B Service Manual Download Page 164](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970164.webp)
SiENBE04-925_A
Indoor Unit
Removal Procedure
149
1.8
Removal of Swing Motors
Procedure
Warning
Be sure to turn off all power supplies at least 10 minutes before
disassembling work.
Step
Procedure
Points
1. Remove the swing motor
for vertical blade.
1
Lift the indoor unit with
a wooden base.
2
Remove the screw
behind the drain hose,
and disconnect the
drain hose.
3
Remove the screw at
the rear, and remove
the screws on the right
and the left side of the
swing motors.
(R10323)
(R10329)
Drain hose
(R10330)
Swing motors
SIENBE04-925_A_FRONT.pdf 164