![Daikin RXL25G2V1B Service Manual Download Page 261](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970261.webp)
Outdoor Unit - RXL35G2V1B
SiENBE04-925_A
246
Removal Procedure
3
Remove the washer-
fitted nut of the outdoor
fan.
The screw has reverse
winding.
Nut size: M6
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
4
Remove the lower 2
screws from the fan
motor first.
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor, the center of
gravity of which is toward the
front, may tilt down or fall,
getting you injured.
5
Then, remove the upper
2 screws.
Step
Procedure
Points
(R5262)
Outdoor fan
10 mm
(R12236)
(R9385)
D-cut
(R9386)
Fan motor
SIENBE04-925_A_FRONT.pdf 261
24/02/2011 13:54:17