![Daikin RXL25G2V1B Service Manual Download Page 198](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970198.webp)
SiENBE04-925_A
Outdoor Unit - RXL20G2V1B9
Removal Procedure
183
3. Outdoor Unit - RXL20G2V1B9
3.1
Removal of Outer Panels / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Appearance features
Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
2. Remove the panels.
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 5 hooks.
1
Remove the screw of
the stop valve cover.
Pull down the stop
valve cover and remove
it.
DAIKIN
INVERTER
(R7186)
(R12288)
(R7188)
Stop
valve
cover
Shield plate
(R7189)
Hooks
SIENBE04-925_A_FRONT.pdf 198
24/02/2011 13:54:08
Summary of Contents for RXL25G2V1B
Page 8: ...SiENBE04 925_A vi Table of Contents ...
Page 14: ...Introduction SiENBE04 925_A xii ...
Page 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Page 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Page 20: ...Specifications SiENBE04 925_A 6 Specifications ...