Removal Procedure
5.4
Removal of PCB
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the cover of
the electrical box.
Preparation
Remove the electrical box
according to the “Removal of
Electrical Box”.
2
Disconnect the
connectors from the
service monitor PCB
[S52] [S102].
3
Detach the 4 clamps
with pliers.
4
Remove the screws of
the terminal board and
the earth wire.
(R9405)
(R5280)
Service monitor PCB
[S52]
[S102]
Clamps
(R5281)
(R12285)
Terminal board
Earth wire
SIENBE04-925_A_FRONT.pdf 269