![Daikin RXL25G2V1B Service Manual Download Page 150](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970150.webp)
SiENBE04-925_A
Indoor Unit
Removal Procedure
135
1.4
Removal of Horizontal Blades / Vertical Blades
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the horizontal
blade (large).
1
Open the horizontal
blade (large).
Caution on Mounting
Mount the large horizontal
blade to the upper side and
the small horizontal blade to
the lower side.
Do not put them in the
wrong place.
2
Unfasten the center
shaft while bending the
horizontal blade (large)
slightly.
3
Unfasten the left shaft.
4
Unfasten the key
alignment shaft at the
right side.
Caution on Mounting
There is a key alignment at
the right shaft. When
mounting, insert the right
shaft first while turning.
After inserting the right
shaft, mount the horizontal
blade first to the center shaft
and then to the left shaft.
(R7921)
Horizontal blade (large)
Horizontal blade (small)
(R7922)
(R7923)
(R7924)