Operation Manual
SiMT041311E
101
Installation / Operation Manual
27
To keep the air conditioner clean
MOLD PROOF operation
< To automatically operate: Default “Off” >
Press for about 2 seconds during operation.
< To cancel the setting >
Press again for about 2 seconds.
< To manually operate >
< To cancel the operation halfway through >
Press .
• The MOLD PROOF / CLEANING FILTER lamp goes out.
Notes on automatic operation
100 minutes
100 minutes
COOLING / “SARARA” DRY / DRY COOLING operation is running.
MOLD PROOF operation is running.
The inside of the air conditioner is dried to reduce the occurrence of mold and odour.
When COOLING, “SARARA” DRY, or DRY COOLING operation is performed, condensation
may occur inside the air conditioner and may cause mold or odour. It is recommended to dry
the inside of the air conditioner by MOLD PROOF operation.
• “ ” is displayed on the LCD.
• MOLD PROOF operation automatically dries the inside of the air
conditioner each time after the COOLING, “SARARA” DRY, or
DRY COOLING operation is stopped.
• The MOLD PROOF / CLEANING FILTER lamp (green) lights up.
• The operation stops automatically in 100 minutes.
• “ ” disappears from the LCD.
Press for about 2 seconds while the unit is not
operating.
• “MOLD PROOF” is displayed on the LCD, and the display
returns to normal after a while.
• The MOLD PROOF / CLEANING FILTER lamp (green) lights
up during the operation.
• The operation stops automatically in 100 minutes.
MOLD PROOF / CLEANING FILTER
lamp (green)
• After COOLING, “SARARA” DRY, or DRY COOLING
operation stops, the air conditioner starts the MOLD
PROOF operation automatically, and then stops
automatically in 100 minutes.
• Even when COOLING is selected in the AUTO
operation, the AUTO MOLD PROOF operation is
started when the AUTO operation is stopped.
• If the operation is turned off by COUNTDOWN OFF
TIMER or OFF TIMER, AUTO MOLD PROOF is not
performed.