Field Settings
SiMT041311E
195
Tips for Servicing
3. Hose length
It sets the length of the humidifying hose.
The longer the length setting is, the higher the humidifying fan rotation frequency becomes.
4. Hose drying
It forces to turn on the humidifying fan and dries the inside of the humidifying hose.
Forced hose drying operation lasts about 30 minutes.
5. RC demo
It shows a sample of the remote controller display. (Ex. information by pressing
INFO
button)
6. AC demo
It starts demonstrational operation of the air conditioner.
7. Defrost QUICK HEAT
It sets defrost operation on/off while the QUICK HEATING TIMER is set. When it is set to
OFF
, the unit does not carry out defrost operation.
8. Circulate setting
When
INSTALLED POSITION
is set to oblong, if the
Circulate setting
is set to
Low
, the
angle of horizontal flaps in circulation airflow becomes same as in case of
INSTALLED
POSITION
is set to horizontal. (The horizontal flaps are set facing a little higher.)
If
Circulate setting
is set to
OFF
, the angle of horizontal flaps in circulation airflow becomes
same as in case of comfort airflow in cooling operation.
9. Shutter setting
It sets the air inlet shutter for on/off. If it is set to off, there will be no bottom air intake.
10.MOLD PROOF STREAMER
It sets the streamer on/off during MOLD PROOF operation. If it is set to off, the streamer will
not be used.
11.Adjust cool Temp.
It sets the amount of room temperature adjustment in cooling operation.
12.Adjust heat Temp.
It sets the amount of room temperature adjustment in heating operation.
13.Humidify unit
It turns on/off humidifying operation.
14.Thermo off setting
It sets the airflow rate when the thermostat is off in cooling operation.
If it is set to
Keep
, the fan keeps rotating at the set airflow rate.
15.Control priority
Do not change the default setting
(Wireless)
.
16.Standby saving
It turns on/off the standby electricity saving function.
17.Preheating
It turns on/off the preheating control.
18.Auto restart
It turns on/off the auto-restart function.