SiMT041311E
Installation Manual
Installation / Operation Manual
64
8
4.
Humidifying hose installation work
4-1 Connecting to the indoor unit
• Connect the cuff side of the
G
humidifying hose to the indoor unit duct.
Duct
Front grille
Cuff
•
Left-side piping
•
Left-bottom piping
•
Left-back piping
Cut the cuff at this point.
Insert the hose into the duct.
4-2 Connecting the cut humidifying hoses
• When installing the cut
G
humidifying hoses, follow the instructions below.
J
Joint
• Use not more than 1 elbow to ensure humidifying capacity.
4-3 How to replace the drain plug and drain hose
•
Replacing onto the left side
How to set drain plug
No gap.
Insert a hexagon wrench (4mm).
Drain hose attachment position
The drain hose is on the back of the unit.
Left side
Right side
Attachment on the left side
Drain hose
C
Drain hose
CAUTION
Use caution not to deform the cuff while installing the humidifying hose. Using a deformed cuff may cause a clopping sound.
It is easier to connect the hose
with the front grille removed.
Insert as far as possible
so that there are no gaps.
G
Humidifying
hose
To pull out the
G
humidifying hose to the right side, turn the
cuff 180˚ from the position shown in the above illustration.
Cut the skirt section of the cuff with
scissors (cut the dotted line section).
Insert each
G
humidifying hose to the rim
of the
J
joint or an elbow (field supply) so
that there are no gaps.
Apply the
K
binding bands at 10mm from the
rim of the
J
joint or an elbow (field supply) to
prevent the
G
humidifying hose from coming off.
Elbow
(field supply)
1) Remove the insulation fixing screw on the right to
remove the drain hose.
2) Reattach the insulation fixing screw on the right as it
was.
Forgetting to attach this may cause water leakages.
3) Remove the drain plug on the left side and attach it to
the right side.
4) Insert the drain hose and tighten with included
C
indoor unit fixing screw.
Do not apply lubricating oil
(refrigerant oil) to the drain plug
when inserting it.
The application of lubrication oil to
the drain plug will deteriorate the
plug to cause drain leakage from
the plug.
Attachment on the right side
(factory default)
Insulation fixing
screw
Indoor unit
fixing screw