Main Functions
SiMT041311E
31
Function and Control
1.9
Sensor Operation
Operation
∗
Refer to the operation manual for details.
1.9.1 3-Area INTELLIGENT EYE Operation
Outline
The 2 INTELLIGENT EYE sensors detect the presence of the user by dividing the room (sensor
range) into 3 areas, to decide whether to blow air directly at or to avoid a person.
The 2 INTELLIGENT EYE sensors judge whether there is a person according to the signals
from the 2 sensors for 3 areas (left, centre, right).
Detail
Comfort or Focus
Comfort
or
Focus
can be selected in remote controller.
Comfort: Adjusts the airflow direction to avoid directly blowing at a person.
Focus: Adjusts the airflow direction to directly blow at a person.
Flap movement
(1) When
Comfort
is set and the INTELLIGENT EYE sensor detects a person
•
Horizontal flap: It blows air downward in heating operation, upward in cooling operation.
•
Vertical flap: It adjusts the airflow to avoid directly blowing at a person.
(2) When
Focus
is set and the INTELLIGENT EYE sensor detects a person
•
Horizontal flap: It adjusts the airflow direction so that the maximum airflow rate is achieved.
•
Vertical flap: It blows air to directly blow at a person.
(R19704)
3-Area INTELLIGENT
EYE / AUTO OFF
Indoor unit
Centre
Right
Left
Top view
(R19764)
Sensor 1
(left)
Sensor 2
(right)