Service Diagnosis
SiMT041311E
123
Service Diagnosis
1. Service Diagnosis
1.1
Indoor Unit
The operation lamp blinks when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated, or when the thermistor
malfunctions.
2. When a signal transmission error occurs between the indoor and outdoor units.
In either case, conduct the diagnostic procedure described in the following pages.
1.2
Outdoor Unit
The outdoor unit has one green LED (LED A) on the PCB. When the microcomputer works in
order, the LED A blinks.
1.3
Remote Controller
Confirm the error code with the remote controller.
Method 1
(1) Open the cover of the remote controller.
(2) Press the
CANCEL
button for 5 seconds pointing the remote controller at the indoor unit.
(3) The display on the remote controller shows an error code with a beep.
(R19676)
Operation lamp (green)
(R19721)
(1)
(2)
(R19722)
(3)