SiMT041311E
Operation Manual
Installation / Operation Manual
108
34
9
CONTRAST
1 to 5
< Note >
10
< Note >
X
Page 28
11
< Note >
12
< Note >
• This function prevents children from operating the remote controller by mistake.
• You can set the contrast between 1 and 5.
The default setting is “3”.
• The higher the figure, the darker the indicator.
• Even if you stop the air conditioner with the remote controller, it continues ventilation for 24 hours until you change the setting to
“Off”.
• The 24 HOUR FRESH AIR SUPPLY VENTILATION starts itself when the circuit breaker has been turned on.
(The OPERATION lamp of the unit is off during the operation. No display is shown on the remote controller.)
• When the 24 HOUR FRESH AIR SUPPLY VENTILATION is solely operated, the streamer discharge cannot be started.
• When the AUTO CLEANING FILTER is set to “On” and the normal operation of the air conditioner stops for 24 hours or longer,
the 24 HOUR FRESH AIR SUPPLY VENTILATION is terminated and the CLEANING FILTER operation starts (and lasts for
about 11 minutes). After the filter has been cleaned, the 24 HOUR FRESH AIR SUPPLY VENTILATION restarts.
• This function sets the contrast of the LCD.
Description
Setting
Menu
No.
The default setting is “1” for both the indoor unit and remote controller.
< To set the address to “2” >
1. Open the front panel, and turn on the circuit breaker.
2. Press .
3. Press to select “RC ADDRESS” and press .
4. Press to select “2”.
5. Press for 2 seconds and send a signal to the indoor unit. The OPERATION lamp
(green) blinks for about 1 minute. (This is not an error blink.)
6. Press the indoor unit ON/OFF switch while the OPERATION lamp is blinking.
Starts 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
Stops 24 HOUR FRESH AIR SUPPLY VENTILATION operation.
24 HOUR
FRESH AIR
Push APPLY
2sec. On
Push APPLY
2sec. Off *
Push APPLY
2sec. 1 *
Push APPLY
2sec. 2
RC
ADDRESS
• This function sets the address when you install 2 indoor units in the same room and do not want to operate them with 1 remote
controller.
When you set one of the indoor units and one of the 2 remote controllers to “2”, the set remote controller can send a signal only
to the set indoor unit.
Press for about 2 seconds to activate the child lock function.
Press for about 2 seconds to cancel the child lock function.
* Default setting
CHILD
LOCK
is displayed and the buttons except is disabled.
Push APPLY
2sec. On
Push APPLY
2sec. Off
If you cannot set the address while
the OPERATION lamp is blinking,
redo this procedure from the first step.