SiMT041311E
Troubleshooting
Service Diagnosis
144
Troubleshooting
Check No.01
Refer to P.181
Check No.12
Refer to P.183
Check No.13
Refer to P.184
Check No.14
Refer to P.184
Note:
OL (Q1M) activating temperature: 120°C
OL (Q1M) recovery temperature: 95°C
(R19728)
Caution
YES
NG
∗
Discharge pipe thermistor
NO
OK
OK
NG
NG
OK
YES
NO
NG
OK
∗
Refrigerant shortage
∗
Water mixed
∗
Stop valve
Disconnect the connector S40
from the PCB. (
∗
1)
Disconnect the
relay connector
for
the OL (Q1M). (
∗
2)
Resistance
∞
Resistance
∞
Nearly 0
Ω
Nearly 0
Ω
∗
Connector S40
∗
Relay connector for OL (Q1M)
∗
2 terminals of OL (Q1M)
Insert the thermistor in
position.
Replace the discharge pipe
thermistor.
Replace the electronic
expansion valve or the coil.
Refer to the refrigerant line
check procedure.
Replace the outdoor unit
PCB.
Replace the four way valve
or the coil.
Replace the outdoor unit
PCB.
Discharge
pipe thermistor
disconnected?
Check No. 01
Check the thermistors.
Check No. 13
Check the four way
valve.
Check No. 14
Check the refrigerant
line.
Check No. 12
Check the electronic
expansion valve.
Replace the relay harness.
Connect the connectors
properly.
Connectors are
properly connected?
Check
the resistance
between the 2 terminals on
the connector S40.
Check
the resistance
between the 2 terminals of
the
relay connector on
the
OL side.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Disconnect the 2 terminals of
the OL (Q1M). (
∗
3)
Resistance
∞
Nearly 0
Ω
Replace the OL (Q1M).
Replace the OL harness.
Check the
resistance between the
2 terminals of the OL
(Q1M).
S40 (
∗
1)
OL (
∗
3)
Compressor
PCB
Relay harness
OL harness
Relay
connector (
∗
2)