SiMT041311E
Operation Manual
Installation / Operation Manual
94
20
Notes on COMFORT SLEEP TIMER operation
< Temperature control of COMFORT SLEEP TIMER operation >
Example (for 6 hours of sleep)
Set temperature
Sleeping hours
During your sleep
After you wake up
0
1
2
3
4
5
6
–1˚C
–2˚C
ON
ON
Wake-up
Wake-up
Wake-up time
Wake-up time
3 hours
3 hours
2 hours
2 hours
1 hour
1 hour
< Humidity control of COMFORT SLEEP TIMER operation >
Example (for 6 hours of sleep)
Standard humidity
0
1
2
3
4
5
6
Sleeping hours
Humidity
MOISTURISING
–10%
2 hours
4 hours
HUMID HEATING: +10%
DRY COOLING: +5%
• When COMFORT SLEEP TIMER is set, the upper limit of the set temperature of HUMID HEATING is 22˚C.
• After the COMFORT SLEEP TIMER operation is finished, the operation displayed on the remote controller will continue.
• If you set the COMFORT SLEEP TIMER while the ON TIMER is set, the ON TIMER will be cancelled.
• Once COMFORT SLEEP TIMER operation starts, the temperature will be lowered 2˚C in the next 3 hours, and then raised
1˚C one hour before you wake up. (V-shaped temperature control)
V-shaped temperature control works most effectively over
periods of 4 or more hours of sleep.
• In DRY COOLING and HUMID HEATING operations, humidity is controlled based on the standard humidity.
Standard humidity is the humidity determined by operation mode and set temperature.
(“STD” is displayed on the LCD.)
• When the preset humidity is “MOISTURISING”, humidity is constantly controlled on a higher level.
(“ ” is displayed on the LCD.)
• In COOLING and HEATING operations, the humidity is not controlled.