DGS-3700 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
Page | 548
M
ONITORING
S
ECTION
12
Table of Contents
Next Section
Previous Section
E
XTERNAL
A
LARM
C
OMMANDS
Back to Section Header
The external alarm commands in the Command Line Interface (CLI) are listed (along with the appropriate
parameters) in the following table.
C
OMMAND
P
ARAMETERS
show external_alarm
config external_alarm
channel <value 1-4> message <sentence 1-128>
Each command is listed, in detail, in the following sections.
show external_alarm
Purpose
Used to display the current external alarm status on the Switch.
Syntax
show external_alarm
Description
This command is used to display the current external alarm status on the Switch.
Parameters
None.
Restrictions
None.
Example usage:
To display the current external alarm on the Switch:
DGS-3700-12:5#show external_alarm
Command: show external_alarm
Channel Status Alarm Message
----------- --------- --------------------------------------
1 Normal External Alarm 1 Occurred!
2 Normal External Alarm 2 Occurred!
3 Normal External Alarm 3 Occurred!
4 Normal External Alarm 4 Occurred!
CTRL+C
ESC
q
Quit
SPACE
n
Next Page
p
Previous Page
r
Refresh
config external_alarm
Purpose
Used to configure the external alarm prompt messages on the Switch.
Syntax
config external_alarm channel <value 1-4> message <sentence 1-128>
Description
This command is used to set the message to be displayed on console when external
alarm occurs.
Parameters
channel
– used to select one of the 4 channels
message
– prompt message
Restrictions
Only Administrator and Operator-level users can issue this command.
Example usage:
To configure the external alarm on channel 1: