DGS-3700 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
Page | 529
DGS-3700-12:5#show cfm mipccm
Command: show cfm mipccm
MA VID MAC Address Port
---------- ---- ----------------- -----
opma 1 00-01-02-03-04-05 2
opma 1 00-01-02-03-04-05 3
Total: 2
DGS-3700-12:5#
cfm linktrace
Purpose
This command is used to issue a CFM linktrack message.
Syntax
cfm linktrace <macaddr> [mepname <string 32> | mepid <int 1-8191> md
<string 22> ma <string 22>] {ttl <int 2-255> | pdu_priority <int 0-7>}
Description
This command is used to issue a CFM linktrack message.
Parameters
<macaddr>
– Specifies the destination MAC address.
mepname
– Specifies the MEP name.
mepid
– Specifies the MEP MEPID.
md
– Specifies the maintenance domain name.
ma
– Specifies the maintenance association name.
ttl
– Specifies the linktrace message TTL value. The default value is 64.
pdu_priority
– The 802.1p priority to be set in the transmitted LTM. If not specified, it
uses the same priority as CCMs sent by the MA.
Restrictions
None.
Example usage:
To create a CFM linktrace:
DGS-3700-12:4#cfm linktrace 00-01-02-03-04-05 mep mep1
Command: cfm linktrace 00-01-02-03-04-05 mep mep1
Transaction ID: 26
Success.
DGS-3700-12:4#
show cfm linktrace
Purpose
Used to show linktrace responses.
Syntax
show cfm linktrace [mepname <string 32> | mepid <int 1-8191> md <string 22>
ma <string 22>] {trans_id <uint>}
Description
The maximum linktrace responses a device can hold is 64.
Parameters
<macaddr>
– Specifies the destination MAC address.
mepname
– Specifies the MEP name.
mepid
– MEP MEPID.
md
– Specifies the maintenance domain name.
ma
– Specifies the maintenance association name.
trans_id
– Specifies the identifier of the transaction to show.
Restrictions
None.