DES-3010F/DES-3010FL/DES-3010G/DES-3016/DES-3018/DES-3026 Fast Ethernet Switch Manual
175
Figure 11- 10. Rx Error Analysis window (table)
The following fields can be set:
Parameter Description
Time Interval [1s]
Select the desired setting between 1s and 60s, where "s" stands for seconds. The default
value is one second.
Record Number [200]
Select number of times the Switch will be polled between 20 and 200. The default value is
200.
Crc Error
Counts otherwise valid packets that did not end on a byte (octet) boundary.
UnderSize
The number of packets detected that are less than the minimum permitted packets size of 64
bytes and have a good CRC. Undersize packets usually indicate collision fragments, a nor-
mal network occurrence.
OverSize
Counts packets received that were longer than 1518 octets, or if a VLAN frame is 1522
octets, and less than the MAX_PKT_LEN. Internally, MAX_PKT_LEN is equal to 1522.
Fragment
The number of packets less than 64 bytes with either bad framing or an invalid CRC. These
are normally the result of collisions.
Jabber
The number of packets with lengths more than the MAX_PKT_LEN bytes. Internally,
MAX_PKT_LEN is equal to 1522.
Drop
The number of packets that are dropped by this port since the last Switch reboot.
Show/Hide
Check whether or not to display Crc Error, Under Size, Over Size, Fragment, Jabber, and
Drop errors.
Clear
Clicking this button clears all statistics counters on this window.
View Table
Clicking this button instructs the Switch to display a table rather than a line graph.
View Line Chart
Clicking this button instructs the Switch to display a line graph rather than a table.
Summary of Contents for DES-3010F
Page 260: ...247 ...