![background image](http://html1.mh-extra.com/html/covidien/closurerfg/closurerfg_operation-manual_2673930041.webp)
Covidien Closur
eRFS
Endovenous Radiofr
equency
Stylet T
reatment
ClosureRFG Radiofrequency Generator
4-5
Stopping RF Treatment
ClosureRFS RF treatment in progress
ClosureRFS
225
Ω
6.0
w
s
0:10
85
°c
2
1
3
2. During treatment, the RF advisory tone sounds every 60 seconds to aid in timing stylet
movement.
Stopping RF Treatment
Warning
If RF treatment does not stop, disconnect the stylet to prevent injury to the patient.
1. When the procedure is done, press the
RF Stop
button
on the screen to stop RF
treatment.
a. The RF Stop button changes from blue to the green RF Start button.
b. The Treatment Timer (3 in the previous illustration) displays the time that RF power
was applied to the stylet in this cycle.
c. The data record (not shown on screen) will contain the total treatment time
(identical to Treatment Time shown on the screen) and one RF treatment cycle.
d. The screen displays “Press RF Button to Treat.”
Important
Do this next step only if treatment was stopped with the intention to continue. The displayed cycle
time will reset to zero and the total treatment time will continue to accumulate with further
treatment.